Hardware · System Integration

PROTOCOL
CONVERTER

Modbus PROFIBUS BACnet IEC 60870

A versatile industrial protocol converter that seamlessly bridges communication between legacy and modern industrial systems. Eliminate integration barriers without replacing existing equipment — simply plug in, configure, and connect.

Get a Quote Download Manual
Protocol Converter Device

KEY FEATURES

Transparent, bidirectional protocol conversion with zero data loss and minimal latency.

🔄

30+ Protocol Support

Simultaneously converts between Modbus RTU/TCP, PROFIBUS DP/PA, BACnet MS/TP & IP, IEC 60870-5-101/104, DNP3, CANopen, M-Bus, and more.

Low-Latency Conversion

Sub-5ms conversion latency ensures real-time responsiveness is preserved across protocol boundaries. Transparent conversion with no data alteration.

🗂️

Flexible Data Mapping

Configurable register and data point mapping with support for scaling, engineering unit conversion, bit manipulation, and custom data type transformations.

🌐

Browser-Based Configuration

Fully configure all conversion parameters through an intuitive web interface — no specialist software or programming expertise required.

🛡️

Industrial Robustness

Surge and transient protection on all ports. Wide operating temperature range. Built to withstand the electrical noise and harsh conditions of industrial environments.

📋

Diagnostic Tools

Built-in packet sniffer, communication statistics, and live register viewer for fast commissioning and troubleshooting without additional test equipment.

CONNECT ANYTHING TO EVERYTHING

The Prizma Protocol Converter is the integration glue that makes heterogeneous industrial networks work. Whether you need to connect a 30-year-old PROFIBUS device to a modern SCADA system, or expose a Modbus meter to a BACnet building management system — our converter handles it transparently.

No programming. No custom drivers. No expensive system redesign. Simply configure the source and destination protocols through the web interface, map your data points, and the converter handles all translation in real time — automatically and continuously.

  • Simultaneous master and slave on multiple protocols
  • Up to 4,000 configurable data points
  • Bidirectional data flow for read and write operations
  • Import/export configuration via CSV
  • Pre-built templates for common device types
  • SNMP monitoring for network management integration
  • Redundant power input for mission-critical applications
Protocol Converter Wiring

SUPPORTED PROTOCOLS

Serial & Fieldbus

ProtocolMode
Modbus RTUMaster / Slave
PROFIBUS DPMaster / Slave
PROFIBUS PAMaster / Slave
DNP3 SerialMaster / Outstation
IEC 60870-5-101Master / Slave
BACnet MS/TPMaster / Slave
M-BusMaster
CANopenMaster / Slave

Ethernet & Hardware

Protocol / SpecDetail
Modbus TCPClient / Server
IEC 60870-5-104Master / Slave
DNP3 TCP/UDPMaster / Outstation
BACnet/IPClient / Server
OPC-UAServer
Ethernet Ports2× 10/100 Mbps
Serial Ports3× RS-485, 1× RS-232
Operating Temp-40°C to +75°C

USE CASES

🔧

Legacy System Integration

Connect older PROFIBUS or serial field devices to modern Ethernet-based SCADA without replacement.

🏢

Building Automation

Bridge Modbus energy meters and HVAC controllers into BACnet building management systems.

Substation Integration

Convert IEC 60870-5-101 serial to IEC 60870-5-104 Ethernet for modern EMS/SCADA integration.

🔋

Energy Management

Aggregate data from M-Bus meters and Modbus devices into a single unified energy management platform.

Break Down Your Protocol Barriers